SCHEDULE OF ACCOMMODATION

Total net floor area 20,021 sq.ft.
74 designated car parking spaces

The Beacon is to be constructed to the highest quality and will comprise a grade A headquarters office building over 3 floors with parking. The building will be designed with sustainability in mind in order to achieve a BREEAM rating of very good. The building has detailed planning consent and we are seeking a pre-let of whole or the majority of the accommodation.

The premises will benefit from:-

  • Air conditioning
  • Raised floors
  • Suspended ceilings
  • Low glare recessed lighting
  • Two passenger lifts
  • Male, female and disabled WC’s and shower facilities

An occupier will have the opportunity to influence the design and create a bespoke building to their requirements during pre-let negotiations.

SCHEDULE

The Beacon Area (sq ft) Area (sq m)
Ground Floor 6,566 610
First Floor 6,566 610
Second Floor 6,889 640
Total 20,021 1,860

74 car parking spaces, plus cycle/motorcycle storage.

SPECIFICATION

Size/configuration

Size   20,021 sq.ft. (1,860 sq.m.)
Façade   Glazed curtain walling and windows, with brickwork and metal panelling.
Reception and Entrance   Double height entrance and reception.
Typical floor size   6,566 – 6,889 sq.ft.
(610 – 640 sq.m.)
Structural grid   7.5m
Planning module   1.5m
Floor Loading   The floor will be designed to allow for 2.5KN/sq.m. over 95% of the lettable area with a 5% high load area of 7.5KN/m.
Acoustic considerations   Windows and curtain walling shall meet all current relevant British Standards and shall take account of appropriate acoustic protection from external noise to achieve a
noise intrusion criteria in the office spaces of LAeq 45dB.
Raised floor   Metal encapsulated tiles on pedestals with 100mm clear void.
Ceiling   Mineral fibre suspended ceiling incorporating flush mounted luminaires.
Roof   Flat roof areas shall be finished in single ply PVC membrane overlaid with uPVC walkway grade tiles for access where required.
 
Mechanical and Electrical

Heating and cooling   Air conditioning.
Lifts   2
Plant   Located at undercroft and roof levels.
General   DDA Fully compliant with the Disability Discrimination Act.
Parking   74 designated spaces. Surface level and undercroft parking,including 3 disabled
spaces. Motorcycle and bicycle spaces.
Toilets   Male, female and disabled WC’s on all floors. Showers One male, female and disabled shower cubicle on ground floor.